24.117.1501    RING AND ARENA REQUIREMENTS

(1) Mixed martial arts contests and exhibitions may be held in a ring or in a fenced area.

(2) A ring specified in (1) must meet the following requirements:

(a) The ring must be no smaller than 20 feet square and no larger than 32 feet square within the ropes.

(b) The ring floor must extend at least 18 inches beyond the ropes. The ring floor must be padded with ensolite or another similar closed-cell foam, with at least a one-inch layer of foam padding. Padding must extend beyond the ring ropes and over the edge of the platform, with a top covering of canvas, duck, or similar material tightly stretched and laced to the ring platform. Material that tends to gather in lumps or ridges is not permitted.

(c) The ring platform must not be more than four feet above the floor of the building and must have suitable steps for the use of the unarmed combatants.

(d) Ring posts must be made of metal, not more than three inches in diameter, extending from the floor of the building to a minimum height of 58 inches above the ring floor, and must be properly padded in a manner approved by the board. Ring posts must be at least 18 inches away from the ring ropes.

(e) Five ring ropes must be used, each rope not less than one inch in diameter and wrapped in a soft material. The lowest ring rope must be 12 inches above the ring floor.

(f) There must not be any obstruction or object, including, without limitation, a triangular border, on any part of the ring floor.

(3) A fenced area specified in (1) must meet the following requirements:

(a) The fenced area must be circular or have at least eight equal sides and must be no smaller than 20 feet wide and no larger than 32 feet wide.

(b) The floor must be padded with ensolite or another similar closed-cell foam, with at least a one-inch layer of foam padding, with a top covering of canvas, duck, or similar material tightly stretched and laced to the platform of the fenced area. Material that tends to gather in lumps or ridges is not permitted.

(c) The platform of the fenced area must not be more than four feet above the floor of the building and must have suitable steps for the use of the unarmed combatants.

(d) Fence posts must be made of metal, not more than six inches in diameter, extending from the floor of the building to between five and seven feet above the floor of the fenced area, and must be properly padded in a manner approved by the board.

(e) The fencing used to enclose the area must be made of a material that will prevent an unarmed combatant from falling out of the fenced area or breaking through the fenced area onto the floor of the building or onto the spectators, including without limitation, chain link fence coated with vinyl.

(f) Any metal portion of the fenced area must be covered and padded in a manner approved by the board and must not be abrasive to the unarmed combatants.

(g) The fenced area must have two entrances.

(h) There must not be any obstruction on any part of the fence surrounding the area in which the unarmed combatants are to be competing.

History: 23-3-405, MCA; IMP, 23-3-404, 23-3-405, MCA; NEW, 2006 MAR p. 1161, Eff. 5/5/06.

Home  |   Search  |   About Us  |   Contact Us  |   Help  |   Disclaimer  |   Privacy & Security