17.50.1806    TENORM WASTE MANAGEMENT SYSTEM LICENSE AND APPLICATION REQUIREMENTS

(1) A person may not construct, expand, or operate a TENORM waste management system after June 27, 2020 without first obtaining a TENORM waste management system license from the department in compliance with ARM Title 17, chapter 50, subchapters 4 and 5 and this subchapter.

(2) An applicant for a TENORM waste management system license shall use the application form provided by the department. In addition to the information required under ARM 17.50.508, the applicant shall provide the following information:

(a) a document signed by the landowner that grants access to the property to the department, private contractors, and the waste management system owner/operator to perform activities associated with regulation and operation of the TENORM waste management system;

(b) technical design specifications;

(c) construction plans;

(d) a detailed site plan that includes:

(i) information concerning any material that will be used to construct a liner or berm, including but not limited to:

(A) type, quantity, and source of waste to be accepted;

(B) compaction density;

(C) moisture content;

(D) design permeability;

(E) liner construction quality assurance and quality control (QA/QC) plans;

(ii) design and location of any proposed storage or treatment areas;

(iii) design and location of any liquid containment or storage structures;

(iv) design, location, and grades of any surface water diversion and drainage structures;

(e) an operation and maintenance plan that complies with ARM 17.50.1808;

(f) a ground water monitoring plan that complies with ARM 17.50.1811; and

(g) a closure plan and a post-closure care plan that complies with ARM 17.50.1812.

 

History: 75-10-204, MCA; IMP, 75-10-204, 75-10-221, MCA; NEW, 2020 MAR p. 1118, Eff. 6/27/20.