(1) In facilities built or extensively remodeled after March 1, 2010, showers, toilets, urinals, and hand washing facilities shall, at a minimum, meet the number required by Table 4.
Table 4. Fixture Ratio Required.
|
First 1500 Males |
First 1500 Females |
Additional Males Over 1500 |
Additional Females over 1500 |
Toilets water closet) |
1:75 for first 1500 |
1:40 |
1:120 |
1:60 |
Hand sinks |
1:200 |
1:150 |
1:200 |
1:150 |
Showers |
1:50 |
1:50 |
1:50 |
1:50 |
(2) A facility may substitute urinals for up to 50 percent of the toilets in the men's room.
(3) All fixtures shall be properly protected as required by the appropriate plumbing code.
(4) All fixtures must be so designed that they may be readily cleaned, disinfected, and maintained.
(5) Hand washing facilities must provide liquid, foam, or powdered soap and either disposable towels with adjacent waste receptacles or hand blowers.
(6) One drinking fountain is required for every 1000 bathers.
(7) A service sink is required for each facility. It shall be located somewhere other than the dressing rooms.