HOME    SEARCH    ABOUT US    CONTACT US    HELP   
           
This is an obsolete version of the rule. Please click on the rule number to view the current version.

24.301.525    REQUIREMENTS FOR DATA PLATE

(1) All factory-built units manufactured or delivered prior to sale or sold or offered for sale in this state must bear a data plate giving the model, serial number, date of completion and design load maximums: i.e., wind, snow, floor live load and seismic design Category D or D1 as applicable.

(2) The data plate must be permanently affixed either to the inside or the outside of the electrical distribution panel door.

(3) The minimum loads acceptable for factory-built units manufactured or delivered prior to sale or sold or offered for sale in this state are:

(a) wind load = 25 psf;

(b) snow load = 30 psf;

(i) For those areas of the state where snow loads are greater than 30 psf, the units must be designed for the greater snow loads.

(c) floor live load = 40 psf; and

(d) seismic design category = D or D1 as applicable.

History: 50-60-203, 50-60-401, MCA; IMP, 50-60-402, MCA; NEW, 1981 MAR p. 514, Eff. 5/29/81; TRANS, from Dept. of Admin. , Ch. 352, L. 1985, Eff. 7/1/85; TRANS, from Commerce, 2001 MAR p. 2301; AMD, 2004 MAR p. 571, Eff. 3/12/04.